Price 13000.0 INR/ Piece

MOQ : 1 Piece

L41 SAFETY LIGHT-BEAM SENSORS Specification

  • Wireless
  • No
  • Sensor Type
  • L41E-21KA1A
  • Ingress Protection
  • III (IEC 61140)
  • Operating Temperature
  • 40 C ... +55 C Celsius (oC)
  • IP Rating
  • IP67 (EN 60529)
  • Features
  • Type 4 (IEC 61496-1) 1)
  • Housing Material
  • Plastic
  • Interface
  • LED
  • Response Time
  • 1 Days
  • Application
  • Monitoring of safety doors
  • Signal Type
  • Digital
  • Power Consumption
  • 30 mA Ampere
  • Cable Length
  • M18 x 97.7 mm Millimeter (mm)
  • Measurement Range
  • 16 m
  • Spectral Range
  • 16 m
  • Power Rating
  • IP67 (EN 60529)
  • Product Type
  • L41E-21KA1A
  • Input
  • SAFETY LIGHT-BEAM SENSORS
  • Output
  • OSSD
  • Function
  • SAFETY SINGLE-BEAM SENSORS
  • Usage
  • Monitoring of safety doors
  • Accuracy
  • 30 mm mm
  • Weight
  • 30 Grams (g)
  • Usage & Applications
  • Monitoring of safety doors
  • Warranty
  • 1 year
  • Cable Type
  • Male connector M12, 4-pin, straight
  • Display Type
  • SAFETY LIGHT-BEAM SENSORS
  • Material
  • Glass
  • Rated Current
  • 70 mA Milliampere (mA)
  • Conductor
  • 15 % ... 95 %,
 

L41 SAFETY LIGHT-BEAM SENSORS Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 1 Week
 

About L41 SAFETY LIGHT-BEAM SENSORS

PRODUCT DESCRIPTION

The L41 single-beam photoelectric safety switch consists of a sender and a receiver. The test input of the sender supports direct functional testing. Performance level PL e to EN ISO 13849 or Type 4 to IEC 61496 can be achieved in conjunction with an evaluation unit. Suitable evaluation units include Flexi Classic or Flexi Soft. Color LEDs provide local information about the operational status. The required sensing range can be selected from various device versions. All devices are suitable for applications in challenging ambient conditions and enable even complex protection tasks to be accomplished by using deflector mirrors.

AT A GLANCE

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849), only in conjunction with suitable testing device, e.g., Flexi Classic or Flexi Soft.
  • Small M18 sensors with ranges up to 10 m.
  • Compact M30 sensors with ranges up to 60 m.
  • Enclosure rating IP 67.
  • Temperature range from 40 C ... +55 C.
  • Radial optics (90 deflector mirror).

YOUR BENEFITS

  • Easy integration due to small, compact versions with maximum range.
  • Directly connect to a safety controller reducing costs.
  • Flexible device integration makes it possible to set up individual access protections.
  • Well suited to withstand extreme ambient conditions such as heat, cold or moisture.

FIELDS OF APPLICATION

  • Access or area protection on machining centers and robot cells.
  • Monitoring of doors and service openings on machines.
  • Optical safety edges for protecting automated guided vehicles.



Highly Reliable Door Monitoring

Engineered for critical safety applications, the L41 SAFETY LIGHT-BEAM SENSORS excel at monitoring safety doors in factories and industrial equipment. Their rapid response and high accuracy ensure hazardous zones are securely managed, immediately detecting any interruption within a 16-meter range. These sensors provide both assurance and compliance in modern safety setups.


Easy Installation and Durable Design

Featuring a compact plastic housing and robust glass optical components, these sensors are easy to install using the M12, 4-pin straight male connector. Their IP67-rated construction provides protection against dust and moisture, making them ideal for use in challenging environments. Maintenance is minimal, aided by indicator LEDs for status monitoring.


Advanced Safety Features

Rated as Type 4 safety devices under IEC 61496-1, the L41 sensors deliver reliable OSSD digital signals for critical safety circuits. Their accuracy of 30 mm and a fast response time further enhance personnel and machinery protection, while their energy-efficient operation supports long-term, cost-effective use.

FAQ's of L41 SAFETY LIGHT-BEAM SENSORS:


Q: How are L41 SAFETY LIGHT-BEAM SENSORS installed in an industrial environment?

A: L41 sensors are designed for straightforward installation using the M12, 4-pin straight male connector. Mount the sensor to monitor safety doors, and connect it to your safety controller or system through the provided cable interface.

Q: What applications are best suited for the L41 SAFETY LIGHT-BEAM SENSORS?

A: These sensors are ideally used for monitoring safety doors in industrial settings, helping safeguard work areas by detecting the presence or absence of obstructions within a 16-meter range.

Q: When should I consider replacing the L41 sensor?

A: While the sensor is designed for durability with a 1-year warranty, replacement is recommended if the sensor displays inconsistent readings, physical damage, or fails during self-test routines as indicated by the LED status.

Q: Where can the L41 sensors be used considering environmental factors?

A: With an operational temperature range of -40C to +55C and an IP67 rating, these sensors are suitable for use both indoors and in environments exposed to dust and moisture.

Q: What is the process for troubleshooting sensor malfunctions?

A: Check the LED indicators for any error codes, ensure all cable connections are secure, verify power and signal output, and consult the product manual for specific troubleshooting steps. Replace if issues persist.

Q: How do the L41 sensors improve workplace safety?

A: By providing rapid and precise detection of obstructions with OSSD output, the L41 sensors help prevent accidental access to hazardous zones and support compliance with safety regulations.

Q: What are the benefits of using a Type 4 (IEC 61496-1) certified sensor?

A: Type 4 certification guarantees the sensor meets stringent safety standards for high-risk applications, ensuring maximum protection for personnel and machinery.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sick Safety Single Beam Sensors Category

L41 SAFETY SINGLE-BEAM SENSORS

L41 SAFETY SINGLE-BEAM SENSORS

Price 13000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Monitoring of safety doors

Usage & Applications : Monitoring of safety doors

Usage : Monitoring of safety doors

Rated Current : 70 Milliampere (mA)



Back to top